<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-31 19-48-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 76 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 69 kHz 18988 0,0105
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,8 dBr 5,85 dBr 7,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Elamasi musiikkia. "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 69 kHz MIN: 9 kHz % above 76 kHz: 0,0105 Acquired: 2025/01/31 19.47.17 Total samples: 18988 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 7,2 dBr MIN: 4,8 dBr AVE: 5,85 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2025/01/31 19.47.16) 19.34 19.36 19.38 19.40 19.42 19.44 19.46 0 2 4 6 8 Pm [dBr]